防排煙管道與排風管道有什么不同

發(fā)布人:http://   發(fā)布時間:2022-06-13 17:40:00

防排煙管道與排風管道的裝置規(guī)范不一樣

The device specifications of smoke control duct and exhaust duct are different

①排煙風道外外表與木質等可燃構件的距離不應小于15㎝,或在排煙道外外表包厚度不小于10㎝的保溫資料進行隔熱。

① The distance between the outer surface of the smoke exhaust duct and wood and other combustible components shall not be less than 15 cm, or the outer surface of the smoke exhaust duct shall be insulated with insulation materials with a thickness of not less than 10 cm.

②排煙風道穿過擋煙墻時,風道與擋煙隔墻之間的空地,應用水泥砂漿等不燃資料緊密填塞。

② When the smoke exhaust air duct passes through the smoke retaining wall, the open space between the air duct and the smoke retaining wall shall be tightly filled with incombustible materials such as cement mortar.

③排煙風道與排煙風機的銜接,宜選用法蘭銜接,或選用不焚燒的軟性銜接。

③ The connection between the smoke exhaust duct and the smoke exhaust fan should be flange connection or non incineration soft connection.

④需要隔熱的金屬排煙道.有必要選用不燃保溫資料,如礦棉、玻璃棉、巖棉、硅酸鋁等資料。

④ Metal exhaust ducts requiring insulation It is necessary to select incombustible insulation materials, such as mineral wool, glass wool, rock wool, aluminum silicate, etc.

QQ截圖20170428145354.png

⑤煙氣排出口的資料應選用耐火性能好的資料制造;排出口的方位應依據建筑物所在的條件確認,有必要避開有焚燒風險的部位。

⑤ The data of flue gas outlet shall be made of data with good fire resistance; The orientation of the exhaust outlet shall be determined according to the conditions of the building, and it is necessary to avoid the parts with incineration risk.

排煙的意圖是將室內的煙塵通過抽風機械排到室外,而通風是能過機械使室內外的空氣進行強制流轉,他們的通風方向和地點就是不同的,

The purpose of smoke exhaust is to exhaust the indoor smoke and dust to the outside through the exhaust machinery, and ventilation is to force the air inside and outside the room through the machinery. Firstly, their ventilation direction and location are different,

其次,他們流轉的空氣質量是不同的,所以不能運用同一個管道,否則,咱們在通風時,不小心把煙塵通到室內,豈不是適得其反.

Secondly, the air quality they circulate is different, so we can't use the same pipe. Otherwise, it would be counterproductive if we inadvertently send smoke and dust indoors during ventilation

排煙管道與排風管道的裝置規(guī)范不一樣,排煙管道系統(tǒng)中要裝置排煙防火閥,而一般的排風管道不用裝置。

The device specifications of smoke exhaust duct and exhaust duct are different. Smoke exhaust fire damper shall be installed in the smoke exhaust duct system, while the general exhaust duct does not use devices.

以上就是濟南風管加工廠http://為大家介紹的內容,感謝您在百忙之中查看我公司的信息內容,如果您想要了解的更多,歡迎您來電進行咨詢!

The above is Jinan air duct processing plant http:// Thank you for checking the information of our company in your busy schedule. If you want to know more, you are welcome to call us for consultation!


上一篇:使用白鐵材質的通風管道的好處?
下一篇:通風管道伸縮節(jié)分類及使用要求